推广 热搜: 二手  BQG350/0.2气动隔膜泵  BQG450/0.2气动隔膜泵  中煤  导轨  电源  东方爱堡  轴承  亏/损  花呗 

美国CIRS 008M躯干体模

点击图片查看原图
 
单价: 面议
起订:
供货总量:
发货期限: 自买家付款之日起 3 天内发货
所在地: 广东 深圳市
有效期至: 长期有效
最后更新: 2019-08-22 15:48
浏览次数: 66
询价
 
公司基本资料信息
详细说明
 美国CIRS 008M躯干体模主要用于放射疗法的测试体模 / MRI躯干体模
The CIRS MRI-LINAC Dynamic Phantom is designed for end-to-end commissioning, machine QA for hybrid MRI-LINAC Radiation Therapy systems, and verification of gated and adaptive treatment plans.

CIRS 008M provides a means to assess MRI image quality, and to test tumor localization and motion-capturing devices. The phantom can be used to acquire moving or static target images for treatment planning and verification of gated or adaptive treatment delivery.



TCIRS 008M, moving rod with target and extended rigid shaft connection are MRI-safe with 1.5T magnets. Motors and motion controller electronics are located at a safe distance from the magnet to ensure MRI image quality. The MRI-LINAC Dynamic Phantom utilizes CIRS Motion Control Software to provide precise, repeatable 3D target motion.


​
CIRS 008M approximates an average human body in size and shape. It is comprised of a plastic shell with a cylindrical thru hole to accommodate a moving rod with simulated target. The shell is filled with proprietary MRI signal-generating gel that allows for quick and easy phantom set-up without liquid motion artifacts. The phantom body is suspended on non-magnetic rails that allow for coil positioning and phantom registration to the couch.nbsp;


美国CIRS 008M躯干体模,CIRS 008M测试体模,CIRS 008M躯干模体

CIRS 008M contains MRI QA targets that are compatible with ACR accreditation program recommendati for:

MRI image spatial distortion
MRI field homogeneity
Laser to ISO center coincidence
The moving insert with simulated target is a sealed, cylindrical rod filled with the same MRI signal-generating proprietary gel as the phantom body. The embedded MRI/CT target is made of MRI gel that provides contrast with respect to the background. This target can receive an ion chamber or other MRI-compatible dosimeters for treatment dose verification. There are laser marks machined on the outside of MRI shell body for both the MRI/CT target and MRI Distortion Grid. To facilitate MRI/CT Image fusion, there is a central fiducial aligned with the exterior laser marks, and in a known position with respect to 3D spatial distortion grid.
美国CIRS 008M躯干体模,CIRS 008M测试体模,CIRS 008M躯干模体特点:
MRI-CT-LINAC Compatiblenbsp;

3D target motion

Gated and adaptive RT plan verification

End-to-end commissioning



MRI QA