 美国CIRS 002H9K测试体模,用于放疗的测试体模。
CIRS offers a variety of IMRT phantoms to match the most common IMRT treatment areas such as prostate, head and neck, breast and lung.

The phantom is ctructed of proprietary tissue equivalent epoxy materials. nbsp;Linear attenuati of the simulated tissues are within 1% of actual attenuation for bone and water from 50 keV to 15 MeV.These unique materials eliminate the need for correction factors, thus improving accuracy and saving time. nbsp;The phantom simulates the patient through the entire process from CT data acquisition and planning to delivery and dose verification.


The Model 002H9K was designed in collaboration with David D. Loshek PhD. nbsp;With the H9K, choose any point dose location within a circular area with diameter of 11.2 cm by simply adjusting the two rotating cylinders. Lung and bone equivalent rods can be positioned at any location within the circular area for assessment of heterogeneity correction. nbsp;Remove the center cylinder from the phantom body to simulate head and neck set-ups.



美国CIRS 002H9K测试体模,放疗测试体模,美国CIRS 002H9K体模


美国CIRS 002H9K测试体模特点:



Ionization chambers, TLD, MOSFET and Diodes easily positioned using interchangeable rods*



Choose any point dose location by rotating the cylinders

Use radiographic film dosimetry - Ready Packreg; and/or GafChromicreg; film

Close placement of detectors to film improves film calibration

CT - film markers ensure accurate film to plan registration

Surfaces are etched with indices for precise alignment

Configure with or without heterogeneities

​

IMRT Verification System

CIRS IMRT phantoms are manufactured from tissue equivalent materials that mimic within 1% from 50 keV to 15 MeV for accurate simulation from CT planning to treatment delivery. nbsp;The interchangeable rod design allows the phantom to accommodate a multitude of dose measurement devices such as ion chambers, TLD, diodes and MOSFET's in the same location within the phantom*. nbsp;Phantom cross secti accommodate GafChromic(r) or standard ready-pack films.(1)s.


*NOTE: This product or an optional accessory of this product requires a CIRS dosimetry cavity code before an order can be placed. Please refer to the Dosimetry Cavity Codes document to identify the CIRS code for the probe you intend to use with this product.nbsp;

The CIRS line of IMRT phantoms is compatible with the RIT 113 software for film to plan analysis. GafChromicreg; is a registered trademark of International Specialty Products, Wayne, NJ.
美国CIRS 002H9K测试体模,用于放疗的测试体模。
CIRS offers a variety of IMRT phantoms to match the most common IMRT treatment areas such as prostate, head and neck, breast and lung.

The phantom is ctructed of proprietary tissue equivalent epoxy materials. nbsp;Linear attenuati of the simulated tissues are within 1% of actual attenuation for bone and water from 50 keV to 15 MeV.These unique materials eliminate the need for correction factors, thus improving accuracy and saving time. nbsp;The phantom simulates the patient through the entire process from CT data acquisition and planning to delivery and dose verification.


The Model 002H9K was designed in collaboration with David D. Loshek PhD. nbsp;With the H9K, choose any point dose location within a circular area with diameter of 11.2 cm by simply adjusting the two rotating cylinders. nbsp;Lung and bone equivalent rods can be positioned at any location within the circular area for assessment of heterogeneity correction. nbsp;Remove the center cylinder from the phantom body to simulate head and neck set-ups.


美国CIRS 002H9K测试体模,放疗测试体模,美国CIRS 002H9K体模


美国CIRS 002H9K测试体模特点:



Ionization chambers, TLD, MOSFET and Diodes easily positioned using interchangeable rods*



Choose any point dose location by rotating the cylindersnbsp;

Use radiographic film dosimetry - Ready Packreg; and/or GafChromicreg; film

Close placement of detectors to film improves film calibration

CT - film markers ensure accurate film to plan registrationnbsp;

Surfaces are etched with indices for precise alignment

Configure with or without heterogeneities



IMRT Verification System

CIRS IMRT phantoms are manufactured from tissue equivalent materials that mimic within 1% from 50 keV to 15 MeV for accurate simulation from CT planning to treatment delivery. nbsp;The interchangeable rod design allows the phantom to accommodate a multitude of dose measurement devices such as ion chambers, TLD, diodes and MOSFET's in the same location within the phantom*. nbsp;Phantom cross secti accommodate GafChromic(r) or standard ready-pack films.(1)s.


*NOTE: This product or an optional accessory of this product requires a CIRS dosimetry cavity code before an order can be placed. Please refer to the Dosimetry Cavity Codes document to identify the CIRS code for the probe you intend to use with this product.nbsp;

The CIRS line of IMRT phantoms is compatible with the RIT 113 software for film to plan analysis. GafChromicreg; is a registered trademark of International Specialty Products, Wayne, NJ.